We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Development syringe pump.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Development syringe pump - List of Manufacturers, Suppliers, Companies and Products | IPROS GMS

Development syringe pump Product List

1~3 item / All 3 items

Displayed results

Development of an automatic management system for plating solution - Syringe Pump XLP6000

Ideal management of plating solutions for semiconductors and electronic components with high reproducibility and precise flow control of the liquid delivery.

Fully compatible with semi-additive manufacturing methods, achieving high reproducibility and easy precise flow rate adjustment, realizing CV of 0.05% at a low cost. Flow rate control from the start with a liquid delivery unit that does not depend on external pressure! Liquid delivery volume range per operation: 1nl to 50ml Volume adjustment unit: minimum 1nl (※) Flow rate range: 0.3μl/min to (5.2nl/sec to) Flow rate adjustment unit: 63nl/min to (1nl/sec) (※) ※ Depends on the capacity of the installed syringe Example: When a 250μl syringe is installed Volume adjustment unit: minimum 5nl Flow rate range: 1.6μl/min to 12.5ml/min (26nl/sec to 208μl/sec) Flow rate adjustment unit: 313nl/min to (5nl/sec) Example: When a 10ml syringe is installed Volume adjustment unit: minimum 0.2μl Flow rate range: 62.5μl/min to 500ml/min (1μl/sec to 8.3ml/sec) Flow rate adjustment unit: 12.5μl/min to (0.2μl/sec to) Robust design reduces service costs for embedded devices and contributes to a lower failure rate of the equipment. High resolution of 6000 or 48,000 steps. Three-way valves to switch liquid paths and up to 12-port valves can be installed.

  • dispenser
  • Syringe Pump
  • Positive Displacement Pump
  • Development syringe pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Development of an automatic dilution device for plating solution - Syringe pump XLP6000

Ideal management of plating solutions for semiconductors and electronic components with high reproducibility and precise flow control of liquid delivery.

Fully compatible with semi-additive manufacturing methods, achieving high reproducibility and easy precise flow rate adjustment, realizing CV of 0.05% at a low cost. Flow rate control from the start with a liquid delivery unit that does not depend on external pressure! Liquid volume range for a single delivery: 1nl to 50ml Volume adjustment unit: minimum 1nl (※) Flow rate range: 0.3μl/min to (5.2nl/sec to) Flow rate adjustment unit: 63nl/min to (1nl/sec to) (※) ※ Depends on the capacity of the installed syringe. Example: When a 250μl syringe is installed Volume adjustment unit: minimum 5nl Flow rate range: 1.6μl/min to 12.5ml/min (26nl/sec to 208μl/sec) Flow rate adjustment unit: 313nl/min to (5nl/sec to) Example: When a 10ml syringe is installed Volume adjustment unit: minimum 0.2μl Flow rate range: 62.5μl/min to 500ml/min (1μl/sec to 8.3ml/sec) Flow rate adjustment unit: 12.5μl/min to (0.2μl/sec to) Robust design reduces service costs for embedded devices and contributes to a lower failure rate of the equipment. High resolution of 6000 or 48,000 steps. Three-way valves to switch liquid paths and 12-port valves can be installed.

  • dispenser
  • Syringe Pump
  • Positive Displacement Pump
  • Development syringe pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Development of superior coating equipment: Syringe Pump XLP6000

The flow rate of the expelled liquid can be adjusted to 0.3 μl/min, minimizing the use of expensive photoresist with nanoliter-level liquid volume adjustments!

Optimal for dropping resist liquid with spin coaters and slit coaters. Affordable with high reproducibility (CV value: 0.05%). Flow rate control from the start by a delivery unit that does not depend on external pressure and flow controllers! Single delivery volume range: 1nl to 50ml Volume adjustment unit: minimum 1nl (※) Flow rate range: 0.3μl/min to (5.2nl/sec to) Flow rate adjustment unit: 63nl/min to (1nl/sec) (※) ※ Depends on the capacity of the installed syringe Example: When a 10ml syringe is installed Volume adjustment unit: minimum 0.2μl to Flow rate range: 62.5μl/min to 500ml/min (1μl/sec to 8.3ml/sec) Flow rate adjustment unit: 12.5μl/min to (0.2μl/sec to) Equipped with a thorough management function for discharge volume and speed using an encoder, as well as a reporting function to notify errors in case of abnormalities. Easy operation linkage with I/O terminals. Maintenance timing is easily managed with the operation amount memory function. Robust design reduces service costs for embedded devices and contributes to a lower failure rate of the equipment. High resolution command with 6000 or 48,000 steps. Three-way valves to switch liquid paths and 12-port valves can be installed.

  • dispenser
  • Syringe Pump
  • Positive Displacement Pump
  • Development syringe pump

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration